StramLiner

  • StramLiner

    An aluminium non-walkable internal finish for roofing applications in both solid & perforated formats

Get in touch

Newsletter

Sign Up

StramLiner

Used in conjunction with the full range of standing seam and box profiled roofing system

Our StramLiner is used in conjunction with our full range of standing seam, and box profiled roofing systems, providing an 0.9mm aluminium non-walkable internal finish for roofing applications in both its solid & perforated formats, and a 0.4mm steel wall liner for wall or cladding applications. Both StramLiner materials and applications hold in place the insulation within a warm roof and wall or cladding built up system, and to provide lateral restraint of the top flange of the purlin or rail.

Profile Description: 32mm x 1020mm

Materials Available*: Aluminium (Non walkable)

Finishes: Plain Mill, Polyester, ARS (PVdf or PVF2 on enquiry).

Gauges: 0.90

Colours: Standard Colours & Special Colours (subject to minimum order)

Steel (Non walkable) – Wall or Cladding Applications ONLY

Finishes: Polyester (Leathergrain, HPS200 Ultra, Sirius on enquiry).

Gauges: 0.40

Colours: Standard Colours & Special Colours (subject to minimum order)

Fixing Specification

Walk Liner Fixings: Intermediate 1 Nr SDIBSW or stainless steel fixings into every trough
End Laps 2 Nr SDIBSW or stainless steel fixings into every trough
Side Laps No requirement for fixing

Walk Liner Sealants: End Laps 1 Row of 6×5 butyl – Class A
Side Laps SDSeal – 50 x 1mm jointing tape

VCL & Airtightness

Primary VCL: Within our low-humidity non-perforated liner systems the VCL is formed by sealing the StramLiner as per the above fixing specification.

Results of air leakage tests based on a 50Pa test:-

As per report No. BP 2395/2/IC/99 (available from technical on request)

Side laps: < 0.1m3/hr/lm

End laps: < 0.1m3/hr/lm

Get in touch

Contact us to discuss your next project, learn more about our roofing and cladding solutions or to see how we can become partners.

StramLiner List